Filter Results By:

Products

Applications

Manufacturers

Showing results: 556 - 570 of 672 items found.

  • DC Sources

    Electronic Test & Power Systems

    Adjustable constant voltage and constant current sources are provided across the entire DC source range. Additionally constant power operation is standard on the high power DC supplies and optional on the medium power models. Modular high current DC power supply systems providing up to 2kV at 2MW can be assembled.A variety of interfaces are available. Analogue, RS232, CAN, RS485, Ethernet or IEEE 488.2 can be specified for most units. LabVIEW drivers are also offered to aid system integration.

  • Test & Measurement

    Mirae Corporation

    High-quality connection solutions for precise measuring, testing and examination. Whether low or medium voltage range, whether precise test runs or preventive measuring and testing: With an extensive portfolio of specific components and cables, Stäubli always ensures perfect and reliable contact between the measuring instrument and the points, objects and systems to be tested. In addition, we are a proven partner of leading manufacturers of measuring instruments in this field, for example for equipping them with high-quality sockets. Every product meets all quality and safety standards.

  • Flow Battery Test Stations

    Greenlight Innovation

    Greenlight's turn-key flow battery test systems include load/power supply modules, automated control of flow, pressure and temperature of electrolyte fluids, cell voltage monitoring, 3-level safety system and computer with Emerald dynamic automation software. All Greenlight flow battery test systems come with a our standard 1 year warranty. Our customer service team is available to travel to your facility for commissioning and training.Greenlight''s Automation Division also offers flow battery assembly equipment.

  • Protector Conductor Test / Ground Continuity Test / Ground Bond Test

    LXinstruments GmbH

    Testing the protective conductor is indispensable for assemblies, devices and systems of protection class I because it reduces the risk of life-threatening electrical accidents.The test checks whether the protective earth (PE) fulfils the criteria specified in the standards and can correctly discharge the current occurring in case of a fault.The ground continuity test checks whether the protective earth conductor is connected continuously to all metallic enclosure parts that can be touched by the user. The test can be carried out with low currents and voltages (simple continuity test).

  • Portable Electricity Meter Testers

    EE-120A-3S + EE-500V-3 - EMSYST Ltd

    The Phantom Load is able to generate three-phase voltages and currents with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current and voltage is individually adjustable. All types of electricity meters – mechanical or electronic, for active, reactive or apparent energy, single-phase or three-phase – can be tested with the Energy Standard. The following meter tests can be carried out with the EE Test System: Error Test, Register Test, No Load Test and Starting Current Test. Full analysis of the customer load can also be performed, if current clamps have been ordered. All test results ( maximum 3 Test Plans, 5 Manual Measurements and Customer Load Analysis) can be saved in one file. 100 saved files can be viewed on the LCD display or transferred to a PC via USB port.

  • Regenerative Battery Pack Test System

    17040 - Chroma ATE Inc.

    Conforms to international standards for battery testing: IEC, ISO, UL, and GB/T, etc.Regenerative battery energy discharge (Eff. >90%, PF >0.95, I_THD <5%)Multiple voltage and current ranges for auto ranging function to provide optimum resolutionHigh accuracy current/voltage measurement (0.05%FS/0.02%FS)2ms current slew rate (-90% ~ 90%)Dynamic (current/power) driving profile simulation tests for NEDC, FUDS, HPPCTest channel parallel functionTest data analysis functionData recovery protection (after power failure)Automatic protection for error conditionBattery simulator (option)High power testing equipment- Voltage range : 80~1000V - Current range : 0~750A - Power range : 0~300kWCustomized integration functions- Integrated temperature chamber - BMS data analysis - Multi-channel voltage/temperature recording

  • Bench Digital Multimeter, Calibrated, 1 kV, 10 A, 3.8 Digit

    72-1015 CAL - Tenma

    The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.

  • Bench Digital Multimeter, Calibrated, Data, 1 kV, 10 A, 3.8 Digit

    72-1015 CAL D - Tenma

    The 72-1015 CAL D from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.

  • Bench Digital Multimeter, Calibrated D & U, 1 kV, 10 A, 3.8 Digit

    72-1015 CAL DU - Tenma

    The 72-1015 CAL DU from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.

  • ESS Performance Test System

    Bloomy Controls, Inc.

    The Energy Storage System (ESS) Performance Test System is used to evaluate, test, and certify the performance of energy storage systems up to 2MW. The system is a configurable platform with over 200 channels of simultaneously measured AC and DC voltages and currents, environmental temperatures, airflow, and communications. Intuitive software provides real-time monitoring and analysis of power, energy and efficiency to adhere with industry standards. The test system interfaces hardware such as load banks, and controls the ESS to simulate utility applications such as peak shaving and frequency regulation.

  • High Power LED Aging Tester

    LS600 - Lisun Electronics Inc.

    • The standard LS600 has 1 Group which has 8 channels. That means LS600 can test 8 LEDs separately at one time. (Optional: it expand to 8 Groups which can test 64 LEDs separately at one time) • Aging Functions: Constant Current, Impact Pulse, On/Off Mode • Output current: 1~1000mA (Special Order Available) • Output voltage: 5V(Special Order Available) • Output frequency: 1~3000Hz, Duty Ratio: 1%-99% • Range of on-off circle: 0~9999h/59m/59s

  • Network Tester

    PeakTech Prüf- und Messtechnik GmbH

    Compact 3½-digit multimeter, developed according to the CAT III 600 V standard with integrated LAN network tester. In addition to the extensive measurement functions for voltage, current and resistance, this model has a fast-reacting continuity test with an acoustic signal and the possibility of performing diode tests. This combination measuring device is a very practical test device that easily shows the correct pin assignment of network cables by comparing a transmitter with the corresponding cable receiver using an LED. Trouble-free checking of cable passage, open, short and cross connect is possible.

  • PXI Matrix Switch: 4x32, 2-Wire, 100Vrms/2A, Armature Relays

    M9120A - Keysight Technologies

    The M9120A high-density matrix offers higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This 2-wire switch matrix provides the durable armature switches allowing multiple channels to be connected at one time, up to 60W per channel. The 4-wire wide bus can be used to route signals between test instruments and the device under test. Choose from the durable connector block or standard cable connections.

  • Wide Range Ohmmeter

    PAS-853B - Prostat Corporation

    - Wide Resistance Measurement Range from 0.01 ohm to 9.99x1012 ohms- Nominal Full Range Tolerance Averages <±5%- Fully Automatic Resistance Range, Test Voltage and Electrification Period Control- Automatic or Continuous Electrification ControlRugged High Performance 80 inches (200cm) Test Leads Included- Powered by one long lasting 9V Alkaline Battery- Large, Easy to Read LCD Display- Meets requirements of ESD Association Standards for material and audit resistance measurement requirements- Certificate of Calibration Traceable to NIST included

  • Dielectric Breakdown Voltage and Dielectric Strength

    ASTM D149 - National Technical Systems

    This test method covers procedures for the determination of dielectric strength of solid insulating materials at commercial power frequencies, under specified conditions. Unless otherwise specified, the tests shall be made at 60 Hz. However, this test method is suitable for use at any frequency from 25 to 800 Hz. At frequencies above 800 Hz, dielectric heating is a potential problem. This test method is intended to be used in conjunction with any ASTM standard or other document that refers to this test method. References to this document need to specify the particular options to be used. It is suitable for use at various temperatures, and in any suitable gaseous or liquid surrounding medium. This test method is not intended for measuring the dielectric strength of materials that are fluid under the conditions of test. This test method is not intended for use in determining intrinsic dielectric strength, direct-voltage dielectric strength, or thermal failure under electrical stress (see Test Method ASTM D3151). This test method is most commonly used to determine the dielectric breakdown voltage through the thickness of a test specimen (puncture). It is also suitable for use to determine dielectric breakdown voltage along the interface between a solid specimen and a gaseous or liquid surrounding medium (flashover). This test method is similar to IEC Publication 243-1. All procedures in this method are included in IEC 243-1. Differences between this method and IEC 243-1 are largely editorial. Note: The above information is taken directly from the test method Scope published in ASTM D149.

Get Help